Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Barat

Bergabung Selama :

BAGIKAN :   

Bagikan :

FLUKE 87V Ex Intrinsically

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0
Dilihat Sebanyak
:
10 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail FLUKE 87V Ex Intrinsically

The 87V Ex Features: ATEX safety rating for use in Ex-zone 1 and zone 2 CAT IV 600 V electrical safety rating Unique function for accurate voltage and frequency measurements on variable speed motor drives ( VSD’ s) Large display with bright, two-level backlight makes the 87V Ex easy to read in all lighting environments Built-in thermometer ( probe included) True-rms ac voltage and current for accurate measurements on non-linear signals 4-1/ 2 digit mode for precise measurements ( 20, 000 counts) Measure up to 1000 V and 10 A ( ac/ dc) Frequency to 200 kHz and % duty cycle Resistance, continuity and diode test 10, 000 ¼ F capacitance range for components and motor caps Min/ Max-Average and Peak capture to record transients and variations automatically Relative mode to remove test lead interference on resistance measurements Auto and manual ranging for maximum flexibility Analog bargraph for fast changing or unstable signals Input Alert provides Safety ratings : ATEX safety rating: II 2 G EEx ia IIC T4 Electrical safety rating: EN61010-1 CAT IV 600 V and CAT III, 1000 V General Specifications Voltage DC Maximum voltage: 1000 V Accuracy: ± ( 0.05 % + 1) Maximum resolution: 10 ¼ V Voltage AC Maximum voltage: 1000 V Accuracy: ± ( 0.7 % + 2) True-rms AC bandwidth: 20 kHz Maximum resolution: 10 ¼ V Current DC Maximum amps: 10 A ( 20 A for 30 seconds maximum) Amps accuracy: ± ( 0.2 % + 2) Maximum resolution: 0.01 ¼ A Current AC Maximum amps: 10 A ( 20 A for 30 seconds maximum) Amps accuracy: ± ( 1.0 % + 2) Maximum resolution: True-rms 0.01 ¼ A Resistance Maximum resistance: 50 M© Accuracy: ± ( 0.2 % + 1) Maximum resolution: 0.01 © Capacitance Maximum capacitance: 9, 999 ¼ F Accuracy: ± ( 1 % + 2) Maximum resolution: 0.001 nF Frequency Maximum frequency: 200 kHz Accuracy: ± ( 0.005 % + 1) Maximum resolution: 0.001 Hz Duty Cycle Maximum duty cycle: 99.90 % Accuracy: ± ( 0.2 % per khz + 0.1 % ) Maximum resolution: 0.10 % Temperature Range: -200.0 ° C to 1090 ° C ( -328 ° F to 1994 ° F) excluding probe 80BK Temperature Probe Range: -40.0 ° C to 260 ° C ( -40 ° F to 500 ° F) Accuracy: 2.2 ° C or 2 % whichever is greater Conductance Maximum conductance: 60.00 nS Accuracy: ± ( 1.0 % + 10) Maximum resolution: 0.001 nS Diode Range: 3 V Resolution: 1 mV Accuracy: ± ( 2 % + 1) Duty Cycle Range Accuracy: Within ± ( 0.2 % per kHz + 0.1 % ) Measurements restriction in Ex-hazardous area Voltage: 65 V Current: 5 A Environmental Specifications Operating Temperature -20 ° C to + 50 ° C Storage Temperature -40 ° C to + 60 ° C Humidity ( Without Condensation) 0 % to 80 % ( 0 ° C to 35 ° C) 0 % to 70 % ( 35 ° C to 50 ° C) Operating Altitude 2000 m Safety Specifications Overvoltage category EN 61010-1 to 1000 V CAT III, 600 V CAT IV Agency Approvals CSA, TÜ V ATEX certification Ex II 2 G EEx ia IIC T4 Agency Approvals ZELM 05 ATEX 0274 Mechanical & General Specifications Size 201 x 98 x 52 mm ( with holster) Weight 12, 5 oz. ( 355 kg) with holster Display ( Digital) 6000 counts updates 4/ sec. 19, 999 counts in high-resolution mod Display ( Analog) 32 segments, updates 40/ sec. Warranty 1 year Battery Life ~ 400 hours typical without backlight Shock 1 Meter drop per IEC 61010-1: 2001 Vibration Per MIL-PRF-28800 for a Class 2 instrument
Tampilkan Lebih Banyak